Details of Product :
- Compliance standard: IEC 61000-4-11 (1994, 2004, 2020 editions for 0–100% output)
- Number of phases: Single-phase
- Test modes: AC/DC, voltage dip, swell, interruption, voltage variation
- Input voltage (EUT): AC 90–264 V, 50/60 Hz; DC 0–125 V
- Output voltage: AC 0 V to input +20% (max. 290 V); DC 0 V to input voltage
- Continuous output power: 4.224 kVA
- Continuous output current: 16 Arms (AC), 16 A (DC)
- 100% input voltage: 16 Arms continuous
- 80% input voltage: 20 Arms (≤5 s)
- 70% input voltage: 23 Arms (≤5 s)
- 40% input voltage: 40 Arms (≤5 s)
- Peak inrush (100–120 V AC): 250 A peak (<10 ms)
- Peak inrush (220–240 V AC): 500 A peak (<10 ms)